Analogue Universal Testing Machines
 
-
 
 
 

Analogue Universal Testing Machines

 
   
   
Analogue Universal Testing Machines India

Tests like Tension, Compression, Transverse, etc. are conducted.
Autographic “Load Vs Elongation” recorder is fitted.
A wide range of metallic materials can be tested.
Optional Accessories such as – Mechanical Extensometer,Load-Stabilizer, Attachments for Brinell test, Tensile test for shouldered & threaded, Single & Double shear test, Bolts-Nuts & Washer test, Rope test, Flat Belt test, Bend-Rebend test, 180° Bend test, Pull-Out test, etc. are available.
Capacities from 100 KN to 1000 KN.( i.e. 10T to 100T)
Loading accuracy well within ±1% conforms to IS: 1828 / BS: 1610.
   
   
   
Measuring Capacity (KN)
100
200
400
600
1000
1’st Range (KN)
0 - 100
0 - 200
0 - 400
0 - 600
0 - 1000
Least Count (KN)
0.2
0.4
0.8
1
2
2’nd Range (KN)
0 - 50
0 - 100
0 - 200
0 - 300
0 - 500
Least Count (KN)
0.1
0.2
0.4
0.5
1
3’rd Range (KN)
0 - 25
0 - 50
0 - 100
0 - 120
0 - 250
Least Count (KN)
0.05
0.1
0.2
0.2
0.5
4’th Range (KN)
0 - 10
0 - 20
0 - 40
0 - 60
0 - 100
Least Count (KN)
0.02
0.04
0.08
0.1
0.2
Overall dimensions approx. (mm)
1950 x 800
x1850
2000 x 800
x 1900
2100 x 800
x 2060
2200 x 800
x 2400
2350 x 800
x 2700
Weight approx (kg)
1200
1300
2100
3100
4100
     
   
   
Measuring Capacity (KN)
100
200
400
600
1000
Max. Tensile Clearance at fully descended piston position (mm)
50 - 700
50 - 700
50 - 700
50 - 700
50 - 850
Max. Clearance for Compression Test
(mm)
0 - 700
0 - 700
0 - 700
0 - 800
0 - 850
Distance between columns (mm)
450
500
500
600
750
Piston Stroke (mm)
150
200
200
250
250
Max. straining speed at no load (mm/min)
300
150
150
100
80
Power Supply
Total H.P.
1.5
1.5
2.5
2.5
4.0
     
    Standard Accessories For All Models :
   
Pair for compression plate dia. (mm)
120
120
120
120
160
For Round Specimen dia. (mm)
10 - 20
10 - 20
10 - 25
10 - 25
10 - 30
For Round Specimen dia. (mm)
20 - 30
20 – 30
25 - 40
25 - 40
30 - 50
For Round Specimen dia. (mm)
-
-
-
40 - 55
50 - 70
For Flat Specimen Thickness (mm)
0 - 10
0 - 10
0 - 15
0 - 15
0 - 22
For Flat Specimen Thickness (mm)
10 - 20
10 - 20
15 - 30
15 - 30
22 - 44
For Flat Specimen Thickness (mm)
-
-
-
-
44 - 65
Max. width of Flat Specimen (mm)
50
50
65
70
70
Adjustable Roller Support of width
(mm)
150
150
150
160
160
Diameter (mm)
30
30
30
50
50
With Max. adjustable clearance (mm)
450
500
500
600
800
Punch tops of radius (mm)
6
6
10
16
16
Punch tops of radius (mm)
12
12
16
22
22
   
We Reserves the rights of change in the specifications due to constant improvements in design.
       
     
   
   
 